Intel
®
Server Board S5000PAL/S5000XAL TPS Light Guided Diagnostics
Revision 2.0
Intel order number: D31979-011
57
7.3 DIMM Fault LEDs
The server board provides a memory fault LED for each DIMM slot.
The DIMM fault LED is
illuminated when the system BIOS disables the specified DIMM after it reaches a specified
number of given failures or if specific critical DIMM failures are detected. See the Intel
®
S5000
Series Chipsets Server Board Family Datasheet for more details.
TP02310
Figure 23. DIMM Fault LED Locations
7.4 Processor Fault LED
The server board provides a Processor Fault LED for each of the two processor sockets. These
LEDs will illuminate when a CPU is disabled or a CPU configuration error is detected.
TP02311
CPU 2 CPU 1
Figure 24. Processor Fault LED Location