Server Technology PT40 Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Mise en réseau Server Technology PT40. Server Technology PT40 Unit installation Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Distribution Unit

© 2005-2008 Server Technology, Inc. All rights reserved. Smart Cabinet Distribution Unit Installation and Operations Manual • CS/CL-3AVx • CS/CL-12V

Page 3 - Table of Contents

Chapter 3: Operations INTERFACES 12 Usernames and Passwords 12 HTML INTERFACE 12 Logging In 13 Power Monitoring 13 Input Feeds ...

Page 4 - Chapter 1: Introduction

Interfaces The Smart Cabinet Distribution Unit has two interfaces: the HTML interface accessed via the HTTP enabled Ethernet connections, and the comm

Page 5 - Equipment Overview

Smart Cabinet Distribution Unit Operations • 13 Installation and Operations Manual Logging In Logging in through HTML requires directing the H

Page 6 - Chapter 2: Installation

14 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Configuration The Configuration section offers access to

Page 7 - Safety Precautions

Smart Cabinet Distribution Unit Operations • 15 Installation and Operations Manual Creating a descriptive Environmental Monitor name: Click on

Page 8 - Mounting

16 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Enabling or disabling SSH server authentication methods:

Page 9 - Connecting to the Unit

Smart Cabinet Distribution Unit Operations • 17 Installation and Operations Manual Setting the data-rate for all serial ports: Select the seri

Page 10

18 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual UPS The UPS Configuration page is used for adding a new U

Page 11 - Chapter 3: Operations

Smart Cabinet Distribution Unit Operations • 19 Installation and Operations Manual Changing a user’s access privilege level: The Sentry has th

Page 12 - HTML Interface

Instructions This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literatu

Page 13

20 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Enabling or disabling the FTP server: The Sentry features

Page 14

Smart Cabinet Distribution Unit Operations • 21 Installation and Operations Manual Configuring input feed traps: Click on the Input Feed Traps

Page 15

22 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the LDAP bind password type: Select Simple or MD5

Page 16

Smart Cabinet Distribution Unit Operations • 23 Installation and Operations Manual Adding and Deleting serial port access: Click on the Ports

Page 17

24 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the ‘To’ email address: Enter the ‘to’ email addr

Page 18

Smart Cabinet Distribution Unit Operations • 25 Installation and Operations Manual Command Line Interface Logging In Logging in through Telnet

Page 19

26 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Administrative Command Summary Add Porttouser Grants a

Page 20

Smart Cabinet Distribution Unit Operations • 27 Installation and Operations Manual Administrative Command Summary (continued) Set Tower 3Phase

Page 21

28 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Operations Commands Operations commands manage outlet sta

Page 22

Smart Cabinet Distribution Unit Operations • 29 Installation and Operations Manual Changing a password: The Password command changes the curre

Page 23

Table of Contents CHAPTER 1: INTRODUCTION 4 Quick Start Guide...

Page 24

30 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Administration Commands Administration commands may only

Page 25 - Command Line Interface

Smart Cabinet Distribution Unit Operations • 31 Installation and Operations Manual Setting user access level privileges: The Set User Access c

Page 26

32 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Input Feed Administration Creating a descriptive infeed n

Page 27

Smart Cabinet Distribution Unit Operations • 33 Installation and Operations Manual Tower Administration Creating a descriptive tower name: The

Page 28

34 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the tower AC voltage type: The Set Tower 3phase c

Page 29

Smart Cabinet Distribution Unit Operations • 35 Installation and Operations Manual Serial Port Administration Creating a descriptive serial po

Page 30

36 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual System Administration Creating a pre-login banner: The Se

Page 31

Smart Cabinet Distribution Unit Operations • 37 Installation and Operations Manual Setting the LED display orientation: The Set Option Display

Page 32

38 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Creating a descriptive tower name: The Set Tower Name com

Page 33

Smart Cabinet Distribution Unit Operations • 39 Installation and Operations Manual Performing a warm boot: The Restart command performs a warm

Page 34

Chapter 1: Introduction Quick Start Guide The following instructions will help you quickly install and configure your Smart CDU for use in your data

Page 35

40 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Displaying network configuration information: The Show Ne

Page 36

Smart Cabinet Distribution Unit Operations • 41 Installation and Operations Manual Telnet Administration NOTE: A restart of the Sentry is req

Page 37

42 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the filename to be uploaded: The Set FTP Filename

Page 38

Smart Cabinet Distribution Unit Operations • 43 Installation and Operations Manual Displaying FTP configuration information: The Show FTP comm

Page 39

44 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Displaying SNTP configuration information: The Show SNTP

Page 40

Smart Cabinet Distribution Unit Operations • 45 Installation and Operations Manual Changing the UPS type: The Set UPS Type command is used to

Page 41

46 • Operations Smart Cabinet Distribution Unit Installation and Operations Manual Changing the UPS SNMP port: With a UPS record configured,

Page 42

Smart Cabinet Distribution Unit Operations • 47 Installation and Operations Manual Adding an infeed to a UPS: The Set UPS AddInfeed command ad

Page 44

Chapter 4: Advanced Operations SSL 50 Enabling and Setting up SSL Support 50 SSL Technical Specifications 50 SSH 51 Enabling and Setting up SSH Supp

Page 45

Equipment Overview 1. The power inlet/cord(s) connects the CDU to the electrical power source. 2. The Input Current LED(s) displays the current lo

Page 46

50 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual SSL Secure Socket Layers (SSL) version 3 enables

Page 47

Smart Cabinet Distribution Unit Advanced Operations • 51 Installation and Operations Manual SSH Secure Shell (SSH) version 2 enables secure ne

Page 48

52 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual SSH Technical Specifications Secure Shell (SSH)

Page 49 - HRESHOLDS 53

Smart Cabinet Distribution Unit Advanced Operations • 53 Installation and Operations Manual SNMP/Thresholds The Sentry family of products supp

Page 50

54 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the trap timer: The Set Traptime command

Page 51

Smart Cabinet Distribution Unit Advanced Operations • 55 Installation and Operations Manual Setting the Trap community string: The Set SNMP Tr

Page 52 - SSH Technical Specifications

56 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Status trap A Status trap is generated when an e

Page 53 - SNMP/Thresholds

Smart Cabinet Distribution Unit Advanced Operations • 57 Installation and Operations Manual Temp Trap The Temp trap is generated whenever the

Page 54

58 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Configuring Traps SNMP Trap Command Summary Com

Page 55

Smart Cabinet Distribution Unit Advanced Operations • 59 Installation and Operations Manual Setting the Infeed Load limit: The Set Trap Infeed

Page 56

6 • Installation Smart Cabinet Distribution Unit Installation and Operations Manual Chapter 2: Installation Before installing your Sentry Sm

Page 57 - Humidity traps

60 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the Humidity sensor threshold limits: Th

Page 58

Smart Cabinet Distribution Unit Advanced Operations • 61 Installation and Operations Manual LDAP The Sentry family of products supports Lightw

Page 59

62 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Enabling and Setting up LDAP Support There are a

Page 60

Smart Cabinet Distribution Unit Advanced Operations • 63 Installation and Operations Manual Setting the LDAP bind password type: The Set LDAP

Page 61 - LDAP Command Summary

64 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the group membership value type: The Set

Page 62

Smart Cabinet Distribution Unit Advanced Operations • 65 Installation and Operations Manual Setting the authentication order: The Set Authorde

Page 63

66 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the DNS IP address: The Set DNS command

Page 64

Smart Cabinet Distribution Unit Advanced Operations • 67 Installation and Operations Manual Setting LDAP group access level privileges: The Se

Page 65 - Example

Displaying LDAP Group access: The List LDAPGroup command displays all access rights for an LDAP group. To display LDAP Group access: At the Smart CD

Page 66

Smart Cabinet Distribution Unit Advanced Operations • 69 Installation and Operations Manual TACACS+ The Sentry family of products supports the

Page 67

Safety Precautions This section contains important safety and regulatory information that should be reviewed before installing and using the Sentry Sm

Page 68

70 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Setting the TACACS+ encryption key: The Set TACA

Page 69 - TACACS+

Smart Cabinet Distribution Unit Advanced Operations • 71 Installation and Operations Manual Displaying TACACS+ configuration information: The

Page 70

72 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Adding serial port access to a TACACS+ account:

Page 71

Smart Cabinet Distribution Unit Advanced Operations • 73 Installation and Operations Manual Logging The Sentry family of products supports log

Page 72

74 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Displaying Syslog configuration information: The

Page 73 - Logging

Smart Cabinet Distribution Unit Advanced Operations • 75 Installation and Operations Manual Changing the SMTP server port: With SMTP support e

Page 74

76 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Displaying Email configuration information: The

Page 75

Smart Cabinet Distribution Unit Advanced Operations • 77 Installation and Operations Manual Upload/Download The Sentry family of product suppo

Page 76

78 • Advanced Operations Smart Cabinet Distribution Unit Installation and Operations Manual Upload/Download Process GETting a configuration

Page 77 - Upload/Download

Smart Cabinet Distribution Unit Appendices • 79 Installation and Operations Manual Chapter 5: Appendices Appendix A: Resetting to Factory Def

Page 78 - Upload/Download Process

Installing the Power Input Retention Bracket For units with a total maximum output <30A, it may be necessary to install the power input retention b

Page 79 - Chapter 5: Appendices

80 • Appendices Smart Cabinet Distribution Unit Installation and Operations Manual Appendix C: Technical Specifications Domestic Models Smar

Page 80 - Smart CDU

Smart Cabinet Distribution Unit Appendices • 81 Installation and Operations Manual Linking Smart CDU Model Rated Voltage Input Cordset and P

Page 81 - International Models

Power Ratings Domestic Models 1 All current ratings are in amperes. Tous les indices de courant sont en ampères. Alle Angaben der Stromstärke erfolg

Page 82 - Power Ratings

Domestic Models (continued) 1 All current ratings are in amperes. Tous les indices de courant sont en ampères. Alle Angaben der Stromstärke erfolgen

Page 83 - Domestic Models (continued)

Domestic Models (continued) 1 All current ratings are in amperes. Tous les indices de courant sont en ampères. Alle Angaben der Stromstärke erfolgen

Page 84

International Models 1 All current ratings are in amperes. Tous les indices de courant sont en ampères. Alle Angaben der Stromstärke erfolgen in Amp

Page 85

Physical Specifications Operating Storage Temperature 32° to 104° F (0° to 40° C) -40° to 185° F (-40° to 85° C) Elevation(above MSL) 0 to

Page 86 - (H x W x D) Weight

Data Connections RS-232 port Smart CDUs are equipped standard with an RJ45 DTE RS-232c serial port. This connector may be used for direct local acces

Page 87 - 67543218

Regulatory Compliance Product Safety Units have been safety tested and certified to the following standards: • USA/Canada UL 60950:2003 and CAN/CS

Page 88

Appendix D: Warranty, Product Registration and Support Warranty For Server Technology Warranty information, please see our website. Product Registrat

Page 89 - Technical Support

Attaching the Expansion Module If supported, connect the Linking Smart CDU with the provided RJ12 crossover cable at the Link port on the Smart CDU. N

Page 90 - Server Technology

Server Technology HEADQUARTERS – NORTH AMERICA EMEA APAC Server Technology, Inc. Server Technology Intl Server Technology, Inc. 1040 S

Commentaires sur ces manuels